Machine Safety Standards for Control Systems: What Manufacturers Need to Know

Machine safety starts with risk assessment, not with hardware. BS EN 60204-1, BS EN ISO 13849-1 and IEC 62061 each do a different job, and the required performance level is an output of the assessment rather than something chosen from a catalogue.

15 September 2026

Safety relays wired beside an Allen-Bradley Stratix switch with port lockouts fitted

Safety is not a component you add at the end. It is a set of functions the control system has to perform reliably enough for the risk they cover, and that reliability is specified before anything is bought.

It starts with risk assessment

The assessment identifies the hazards, judges severity, frequency of exposure and how far the hazard can be avoided, and produces a required performance level or safety integrity level for each safety function. Everything downstream follows from that. Choosing a safety relay first and assessing afterwards is the wrong order, and it is the common one.

The three standards and what each does

  • BS EN 60204-1 covers the electrical equipment of machines: supply disconnection, protection against shock, emergency stop categories, conductor identification and the stop categories 0, 1 and 2
  • BS EN ISO 13849-1 covers safety-related parts of control systems, expressed as performance levels PL a to PL e, using category, MTTFd, diagnostic coverage and common cause failure
  • IEC 62061 covers functional safety of safety-related control systems of any technology, expressed as safety integrity levels

Standard PLC or safety PLC

A standard PLC executes a program. A safety PLC runs a certified safety operating system on redundant, self-checking hardware, with diagnostics designed to detect its own faults and drive outputs to a safe state. A standard controller running logic labelled "safety" in the program is not a safety system, whatever the tag names say.

Emergency stops are not the safety system

An emergency stop is a complementary protective measure. It is not a substitute for guarding, interlocking or prevention of unexpected start-up. Guard switches need to be selected and mounted so they cannot be defeated with a spare actuator, and the stop function on a drive, whether safe torque off, a safe motion function or a contactor, needs choosing for the stop category the risk assessment calls for.

Modifications change the requirements

Adding a conveyor, changing a guard, or increasing a speed can change the risk assessment and the required performance level with it. Safety functions also need validating and maintaining: an interlock that has been bypassed for six months is not a safety function.

We design safety into machine control rather than bolting it on afterwards. See machine control systems.

Ready to talk through your automation challenge?

Tell us what the system needs to do, or what it is doing that it should not. You will speak to an engineer, not an account manager.

Speak to an Engineer+44 1933 677 550sales@stratoscontrols.com